7 Drive Machine Data (SIMODRIVE Drive MD)

12.93

7.2.2 FDD MD (data description - SW 3)

n

min

for n

act

< n

min

1418

Default value

Lower input limit

Upper input limit

Units

0

0

7 200

rev/min

Active

at once

Input of threshold speed for monitoring purposes; if the actual speed value does not reach the
set threshold speed in terms of absolute value, a message is transferred to the SERVO. The
monitoring function is not activated unless the default value is changed.

Time constant integrator feedback

1421

Default value

Lower input limit

Upper input limit

Units

0.0

0.0

1 000.0

ms

Active

at once

The speed controller loop integrator is reduced via a weighted feedback to a low-pass
response of the 1st order with the configured time constant. Machining movements via the
integrator in the case of non-linear controlled system characteristics (friction around the zero-
speed point) can thus be restricted or prevented.

Note:

The integrator feedback is activated when MD 1421 is set to 1.0.

Time constant speed setpoint filter

1502

Default value

Lower input limit

Upper input limit

Units

0

0

500

ms

Active

at once

Input of time constant for speed setpoint filter (PT1 low-pass). The filter is deactivated when
the data is set to zero.

Concealable power on 611D alarms

1600

Default value

Lower input limit

Upper input limit

Units

0000

0000

FFFF

Hex

Active

at once

This machine data allows power on 611D alarms to be concealed. The monitoring function is
activated if the appropriate bit = 0. All 611D monitoring functions are activated as standard.

7–68

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)