Siemens SINUMERIK 840C User Manual

Page 941

Advertising
background image

12 Functional Descriptions

12.93

12.18.13 Start-up

Setting the interlocks

To complete the start-up procedure, you now need to set or reset the interlock or enable bits
for certain GI functionalities according to the machine manufacturer's data. The following
settings are available:

NC MD 1456*/496*

Default setting of link structure

NC MD 1844*/525* bit1

Reconfiguration permissible

NC MD 1844*/525* bit2

Switchover of link factor permissible

NC MD 1844*/525* bit3

Overwriting of positions permissible

NC MD 1844*

bit4

LINK_ON after power on

12.18.14

Special cases of gearbox interpolation

12.18.14.1 Synchronous spindle

If only the "Synchronous spindle" option is set, then several pairs of

synchronous spindles can be configured. The selected gearbox

interpolation type is subject to the following restriction:

Only one leading spindle can be configured for each following spindle.

The synchronous spindle function is especially important for the "on-the-fly transfer" of the
workpiece from the working spindle. During this process, the workpiece is transferred to the
synchronous spindle (following/counter-spindle) while the main (leading) spindle is rotating. In
this case, the synchronous spindle must be synchronized with the main spindle in terms of
speed and, with shaped workpieces, also in terms of position.

The synchronous spindle is programmed by means of the G400, G401, G402 and G403
commands in conformity with the general programming options for gearbox interpolation.

The interface signal INTERLOCK LINK ON can also be applied in this case to influence the
activation and deactivation of the gearbox link from the PLC.

The following special features must be noted with respect to the "Synchronous spindle"
functionality or following spindles:

POWER ON/Ramp-up/Start-up

The leading and following spindles are always in the spindle mode after POWER ON. LINK
ON cannot be activated after POWER ON in this case (in contrast to axes).

A pulse encoder must be provided for the leading and following spindles.

The spindle drift must be compensated.

The position control loops of the spindles must be set to the same following error for a
setpoint link.

The leading and following spindles are always operated under position control in
synchronous operation.

If a simulated spindle is to act as the leading spindle, NC MD 520*.2 (pulse encoder
installed) and the NS SPEED CONTROLLER ENABLE must be set for the spindle (even
when a pulse encoder is not connected).