Siemens SINUMERIK 840C User Manual

Page 574

Advertising
background image

04.96

7 Drive Machine Data (SIMODRIVE Drive MD)

7.3.2 Drive MD (data description)

Significance speed representation

1711

Default value

Lower output limit

Upper output limit

Units

0.0

-100000.0

100000.0

rev/min

Active

at once

This machine data is used to display the significance of the speed representation. The user is
informed of the significance of bit 0 (internal speed actual value representation) so that he can
assign the internal speed status representation to the physical rotation values. A speed is
available internally in the units of the encoder system and referred to the currently valid speed
controller cycle.

Note:

This machine data is calculated only once during power-up; it cannot therefore be changed
during operation.

Significance rotor flux represent.

1712

Default value

Lower output limit

Upper output limit

Units

0.0

-100000.0

100000.0

µ

Vs

Active

at once

This machine data is used to display the significance of the rotor flux representation. The user
is informed of the significance of bit 0 so that he can assign the internal rotor flux status
representation to the physical values in Vs. The rotor flux scaling is available as an internal
data.

Note:

This machine data is calculated only once during power-up and from the power ON data after
every motor switchover.

Significance torque representation

1713

Default value

Lower output limit

Upper output limit

Units

0.0

-100000.0

100000.0

µ

Nm

Active

at once

This machine data is used to display the significance of the torque representation. The user is
informed of the percentage significance of bit 0 so that he can assign the internal torque status
representation.

Note:

This machine data is calculated only once during power-up from power ON data.

Significance rotor position representation

1714

Default value

Lower output limit

Upper output limit

Units

-

-100000.0

100000.0

Degrees

Active

at once

This machine data is the display data of the significance of the rotor position representation.
The user is given the significance of bit 0 so that he can assign the internal representation of
the rotor position to the physical values in electrical degrees.

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

7–159

SINUMERIK 840C (IA)

Advertising