7 Drive Machine Data (SIMODRIVE Drive MD)

04.96

7.3.2 Drive MD (data description)

Example: Low-pass

Low-passes and band-stops are used in damping resonances above and at the limit of stability
of the speed control loop (see diagrams below).

Specified: Natural frequency 500 Hz with 0.2, 0.5 or 1.0 input

1

10

Log

1k

180

Phase

Deg

-180

10 kHz

100

500

Natural frequency

1.0
0.5
0.2

1

10

Log

1k

10 kHz

20.0

0.0

dB

-60.0

100

500

0.2
0.5
1.0

Example: Band-stop filter

Specified: Blocking frequency 1 kHz with 1 kHz bandwidth 0 Hz bandwidth numerator
(damping)

Band width

20.0

0.0

-3.0

dB

-60.0

1

10

Log

1k

10 kHz

100

Blocking frequency

1

10

Log

1k

10 kHz

180

Phase

Deg

-180

100