7 Drive Machine Data (SIMODRIVE Drive MD)

04.96

7.3.2 Drive MD (data description)

Drive operating modes Emergency retraction

1636

Default value

Lower input limit

Upper input limit

Units

0

0

7

-

Active

at once

Input to select various operating modes in the drive operating modes word. It defines 8
operating modes for the following cases of failure:

Sign-of-life failure

DC-link voltage < MD 1633 or MD 1631

Activation of the autonomous drive emergency retraction through the NC

Table Drive operating modes Emergency retraction

Value input

Operating mode

0

Normal mode

1

Monitoring mode

2

Delayed regenerative braking

3

Delayed regenerative braking only with sign-of-life failure

4

Emergency retraction

5

Emergency retraction only with sign-of-life failure

6

Generator operation with possible return to normal mode

7

Generator operation without possible return to normal mode

This machine data is relevant only for Siemens-internal purposes and must

not be altered.

Delay time regenerative braking

1637

Default value

Lower input limit

Upper input limit

Units

0

0

10000

ms

Active

at once

Input of the time delay by which regenerative braking is delayed in the case of a failure.

This machine data is relevant only for Siemens-internal purposes and must

not be altered.

Input of the emergency retraction time, for which the emergency retraction speed (MD 1639) is
given as setpoint speed in the case of a failure.