6 NC Machine Data (NC MD), NC Setting Data (NC SD)

04.96

6.7 Axis-specific MD 2 (axial data 2)

Feedforward control factor 4th - 7th parameter set

3)

1184*-

1196*

Default value

Lower input limit

Upper input limit

Units

0

+0

1 000

0.1%

Active on

NC Stop

This MD has the same meaning as MD 312*, see also functional description of parameter set
switchover.

Delay for contour monitoring

1200*

Default value

Lower input limit

Upper input limit

Units

0

0

16 000

ms

Active in all

channels of

mode group

in STOP

With this MD, it is possible to set a time where the contour deviation may exceed that of MD
332

*

without an alarm message ”Contour monitoring” being output.

f: Pulse multiplication EXE/611D/HMS 2nd measuring

system

1)

1204*

Default value

Lower input limit

Upper input limit

Units

1

1

128

1)

512

2)

Active on

Power On

Active:

After POWER ON

The matching of the internal computing precision and the precision of the second measuring
system is carried out in the same way as the settings for the first measuring system
(MD 364*/368*/1116*).

_______

1)

As from SW 2

2)

As from SW 3

3)

As from SW 4