10.94

6 NC Machine Data (NC MD), NC Setting Data (NC SD)

6.4 Axis-specific MD 1 (axial data 1)

Reference point value

240*

Default value

Lower input limit

Upper input limit

Units

0

±0

99 999 999

units (MS)

Active on
NC Stop

The difference between absolute machine zero and the fixed reference point is entered for the
respective axis. These values are set as actual values for reference point approach (also refer
to Section entitled ”Axis (Analog) and Spindle Installation” for a detailed description of
reference point approach).

Example: Turning machine

Z+

Workholder

ZMR

X+

R

XMR

W

Workpiece

M

M

...

Machine zero

W

...

Workpiece zero

R

...

Reference point

XMR

...

Reference point coordinate in X direction

ZMR

...

Reference point coordinate in Z direction

©