Siemens SINUMERIK 840C User Manual

Page 419

Advertising
background image

7 Drive Machine Data (SIMODRIVE Drive MD)

10.94

7.1.2 MSD MD (data description - SW 3)

Rounding degree speed setpoint

19

Default value

Lower input limit

Upper input limit

Units

0

0

30

Active

at once

Input of parameter setting for a PT2 filter (low-pass) in the speed setpoint channel. The low-
pass filter is inserted on the output side of the ramp-function generator and is effective only if
the speed setpoint smoothing function (MD 53, bit 4) is activated at the same time.

Diagnosis speed actual value

20

Default value

Lower output limit

Upper output limit

Units

0000

0000

Hex

Active

at once

Display of the monitoring machine data "Diagnosis speed actual value". If an impermissibly
large speed deviation occurs within the sampling period, then the value of the machine data is
incremented. Sporadic responses by a few increments can be ignored since these do not
influence the speed controller. A high disturbance level will cause the contents of MD 20 to be
increased repeatedly by several increments.

Possible causes of disturbances

Encoder shield not earthed

Encoder defective

Earth connection of electronics ground in MSD module faulty

Motor earth not connected in MSD module

Value entered for motor moment of inertia too high

Evaluation electronics

n

min

for n

act

< n

min

message motor 1

21

Default value

Lower input limit

Upper input limit

Units

12

0

Rated speed

rev/min

Active

at once

Input of response value for monitoring of the PLC status message n

act

< n

min

(see also

MD 241).

Creep speed pulse suppression motor 1

22

Default value

Lower input limit

Upper input limit

Units

Rated speed

––––––––––––––

256

0

Rated speed

rev/min

Active

at once

Input of response value for the internal n

min

sensor for stopping the drive with no reverse

rotation. When the speed n

min

is reached, the drive torque is cut off and the drive coasts to a

stop with any remaining kinetic energy.

Note:

This n

min

threshold is not the same as the response value of the n

min

monitor, but it may be

set to the same value.

7–4

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)