7 Drive Machine Data (SIMODRIVE Drive MD)

07.97

7.3.2 Drive MD (data description)

Response threshold dn/dt

1611

Default value

Lower input limit

Upper input limit

Units

800

0

1 600

%

Active

at once

Input of response threshold for dn/dt monitoring function.

Caution:

This machine data is required for the load test. It is relevant only for internal Siemens
processes and must not be altered.

Config. shutdown react. PO alarms

1612

Default value

Lower input limit

Upper input limit

Units

0DBC/FFFF

0000

FFFF

Hex

Active

at once

Input bit field for switching over the appropriate 611D power ON alarm. It is possible to select
one of two shutdown reactions, i.e. pulse disable (bit = 1) or controller disable (bit ˆ

=0 =

n

set

ˆ

=0 = generator-mode braking), i.e. when the pulse disable reaction is selected, the

controller disable reaction is deactivated. The default setting is dependent on the motor type
(FDD ˆ

=0D3C, MSD ˆ

=FFFF) and is parameterized by the drive configuration during start-up.

Note:

The MSD default setting (FFFF) must be selected when the FDD H option is used.

Caution:

The alarms may be deactivated or concealed through machine data MD 1600 - Concealable
alarms (power ON), i.e. they may be inactive.

Value table:

Bit 0

Pulse disable in response to internal
errors/faults

1 = on
0 = off

Bit 1

Not assigned

Bits 2-5

Reserved

Bit 6

Pulse disable NC sign-of-life (as from SW 6)

1 = on (MSD)
0 = off (FDD)

Bit 7

Bit 8

Pulse disable, zero monitoring

1 = on
0 = off

Bit 9

Pulse disable, converter limit frequency

1 = on
0 = off

Bits 10-11

Reserved

Bits 12-14

Not assigned

Bit 15

Pulse disable, heat sink temperature

1 = on
0 = off

*

) As from SW 5.2 (840C) reserved; prior to SW 5.2 always bit 7=1

7–138

©

Siemens AG 1992 All Rights Reserved 6FC5197- AA50

SINUMERIK 840C (IA)