Siemens SINUMERIK 840C User Manual

Page 97

Advertising
background image

09.95

Siemens AG 2001

All Rights Reserved

6FC5197–

j

AA50

4–34

SINUMERIK 840C (IA)

BPOSNEG_DEF

The parameter BPOSNEG_DEF sets whether the screen display is to be in posi-
tive mode (enter PO) or in negative mode (enter NE).

You can enter PO or NE here but be sure to enter the parameter in capital letters.

Positive mode means black lettering on a white background and negative mode
means white lettering on a black background.

BSCREENSAVE

The parameter BSCREENSAVE defines the time after which the screen saver of
the operator panel will darken the screen if no input has been made. The default
3600000 defines a time delay of two hours. The value must be positive,d a value
of 500 represents a delay of one second.

You can switch off the screen saver by placing the comment characters in front of
the value, (e.g. // a 1 7 0 3600000 ).

Note

CLUT :

Color Look-up Table

MO

:

Monochrome mode

CO

:

Color mode

PO

:

Positive mode

NE

:

NEGATIVE mode

Caution!
There is also a screen saver in the PLC (DB48).

BANZLINESMZ_DEF

The parameter BANZLINESMZ_DEF

The number of lines in the message line, either one or two, is defined in
BANZLINESMZ_DEF.

The following values are permissible:

1:

one-line message line

2:

two-line message line

Values

i 1 2 15000

2

BANZLINESMZ_DEF

BAEFCOLOR_DFLT

The ASCII editor is preset with the values. The value in BAEFCOLOR_DFLT de-
fines the foreground color. Values from 0 to 7 are permissible (see color look-up
table).

BAEBCOLOR_DFLT

The parameter BAEBCOLOR_DFLT line 134 defines the background color. Va-
lues from 0 to 7 are permissible.

Values recommended for monochrome display:

CLUT

POMOCLUT

POCOCLUT

NEMOCLUT

NECOCLUT

Foreground

Line 133

5

0

7

7

Background

Line 134

7

7

0

0

4 MMC Area Diagnosis