12 Functional Descriptions

01.99

12.19.5 Interpolation and compensation with tables

5. Deactivate and retract

N0250 @40c K11 K2 K0

- Deactivate IKA 2

@714

G200 Y

- Synchronization of actual value system

N0255 G0 Y200

- Retract

N0260 X300

N0270 @100 K300

Jump to end

6. Errors

N0281 M00 (error 1)

T55=1: only one pointer <> 0 !

@100 K300

N0282 M00 (error 2)

T55=2: End pointer <= start pointer!

@100 K300

N0283 M00 (error 3)

T55=3: Input[n+1] <= input[n] !

N0285 @30c R31 K56 K1

- Read current point number n [> R31]

@100 K300

N0284 M00 (error 4)

T55=4: Gradient > 1 !

N0285 @30c R31 K56 K1

- Read current point number n [> R31]

7. End

N0300 M02

IKA status displays in T55 and T66

Code

Text

Significance

-2

Running

Calculation running

-1

Requested

Calculation requested

0

Calculated

Curve calculated

1

0 pointer

Start or end pointer is equal to zero

2

Start > End

Start pointer is greater than stop pointer

3

Position point

The position of one point is wrong

4

Gradient point

Gradient of one point is wrong.
The point is then stored in T56.

5

Both pointers in the table are zero.

12–198