C00498 | open-circuit monitoring, C00498, 17 parameter reference – Lenze 8400 TopLine User Manual

Page 1000

Advertising
background image

17

Parameter reference

17.2

Parameter list | C00498

1000

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00498

Parameter | Name:

C00498 | Open-circuit monitoring

Data type: UNSIGNED_8

Index: 24077

d

= 5E0D

h

Configuration of open-circuit monitoring for encoder/feedback system

• We recommend using the Lenze setting.

• The settings 1 ... 3 make sense if the respective encoder is not to be used as speed encoder or position encoder

but within the scope of the application. Moreover, a directed disconnection of the monitoring is possible.

Encoder/feedback system

Selection list

Info

0 Speed and position encoder

Open-circuit monitoring is active for the speed encoder

selected in

C00495

and the position encoder selected in

C00490

.

• Depending on whether a speed encoder or position

encoder has been selected, the monitoring mode for

the resolver and/or encoder is activated.

• If no speed encoder and position encoder have been

selected, open-circuit monitoring is deactivated.

1 Resolver only

Open-circuit monitoring is only active for the resolver,

independent on the selection of the speed encoder and

position encoder.

• Open-circuit monitoring for the encoder is

deactivated.

2 Encoder only

Open-circuit monitoring is only active for the encoder,

independent on the selection of the speed encoder and

position encoder.

• Open-circuit monitoring for the resolver is

deactivated.

3 Resolver and encoder

Open-circuit monitoring is active for the resolver and

encoder, independent on the selection of the speed

encoder and position encoder.

Subcodes

Lenze setting

Info

C00498/1

0: Speed encoder and position

encoder

Open-circuit monitoring

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising