Parameter reference

17.2

Parameter list | C00960

1128

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00960

C00961

C00963

Parameter | Name:

C00960 | L_Curve_1: Selected curve type

Data type: UNSIGNED_8

Index: 23615

d

= 5C3F

h

FB

L_Curve_1

: Selected curve type

Selection list

0 Out = 0
1 Out = In
2 Out = f(In)
3 Out = f(table)

Subcodes

Lenze setting

Info

C00960/1

1: Out = In

L_Curve_1

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00961 | L_Curve_1: Input limitation

Data type: INTEGER_16

Index: 23614

d

= 5C3E

h

FB

L_Curve_1

: Upper and lower limit for input value

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C00961/1

199.99 %

L_Curve_1

: Max. input

C00961/2

-199.99 %

L_Curve_1

: Min. input

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00963 | L_Curve_1: Table X-values

Data type: INTEGER_16

Index: 23612

d

= 5C3C

h

FB

L_Curve_1

: X-values for characteristic function

Setting range

(min. value | unit | max. value)

-32767

32767

Subcodes

Lenze setting

Info

C00963/1

0

X values 1 ... 32 for characteristic function

C00963/...
C00963/32

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1