C02589

Bit 6  SyncRampe L_NSet_1

From version 02.00.00

Selection of the ramp time for the synchronisation

process to setpoint speed after the brake opening time

has elapsed

Revised behaviour from version 02.00.00:

• 1 ≡ The ramp time of the effective acceleration of the

ramp function generator (

L_NSet_1

) is used (Lenze

setting).

• 0 ≡ As before, the ramp time set in

C02610/1

is used.

Note:

The changeover can be dynamically both via the ramp

parameter and via bit 6.

Bit 7 

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02582 | Holding brake: Setting

Data type: UNSIGNED_8

Index: 21993

d

= 55E9

h

Parameter | Name:

C02589 | Holding brake: Time system

Data type: UNSIGNED_16

Index: 21986

d

= 55E2

h

Operating times of the holding brake

• The electromechanical delay times of the holding brake are specified in the data sheets or on the holding brake

nameplate.

Holding brake control

Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C02589/1

100 ms

Holding brake: Application time

• Time in which the holding brake is completely applied

from the beginning of control and in which the

controller is inhibited.

C02589/2

100 ms

Holding brake: Release time

• Time in which the holding brake is completely

released from the beginning of control.

C02589/3

100 ms

Holding brake: Waiting time status

• Time after which all transient reactions are

completed and the switching status of the holding

brake is stable. Beginning of monitoring the feedback

signal for the switching status of the holding brake.

C02589/4

0 ms

Holding brake: Ramp time FF ctrl

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1