4 starting recording, 5 adjusting the representation, Starting recording – Lenze 8400 TopLine User Manual

Page 740: Adjusting the representation, Adjusting the representation ( 740), 11 oscilloscope function

Advertising
background image

11

Oscilloscope function

11.3

Operation

740

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.3.4

Starting recording

Click Start to start recording.

To obtain a maximum sample rate when recording the variable values, the data are first stored in

the measured data memory of the 8400 TopLine and then transferred as a data set to the

Engineering PC. The current recording status is displayed in the status bar.

11.3.5

Adjusting the representation

After the variable values have been recorded and the online data set has been transferred to the

Engineering PC, the data set is visualised in the oscillogram. If required, the representation can now

be adjusted by using the zoom or the automatic scaling function.

Tip!
When the oscillogram does not show the complete measurement, a scrollbar appears

below the time axis. You can use this scrollbar for horizontal scrolling of the visible area.

The labelling of the time axis and the position display are automatically adapted.

Selection of the horizontal display position
The Position input field can be used to change the horizontal display position.

• The position value can be directly entered into the input field or selected using the arrow

buttons.

• When the arrow buttons are used and the <Ctrl> key is pressed, you can increase the step size

to accelerate the shift.

Subsequently changing the time base
Change the time base to stretch or compress measurements that have already been completed.

Zoom function

Go to the oscilloscope toolbar and click the

icon to activate the zoom function.

Note!

Recording can only be started when an online connection has been established to the

8400 TopLine.

Advertising