Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1011

17

Parameter reference

17.2

Parameter list | C00571

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00571

C00572

C00574

C00576

Parameter | Name:

C00571 | Resp. to wrong controller setting

Data type: UNSIGNED_8

Index: 24004

d

= 5DC4

h

From version 14.00.00

Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C00571/1

6: Information

Resp. to: Motor control does not match motor data

C00571/2

1: Fault

Resp. to a non-set speed controller

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00572 | Brake resistor overload threshold

Data type: UNSIGNED_8

Index: 24003

d

= 5DC3

h

Adjustable threshold for monitoring the brake resistor utilisation

• The response for reaching the threshold can be selected in

C00574

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 100 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00574 | Resp. to brake resist. overtemp.

Data type: UNSIGNED_8

Index: 24001

d

= 5DC1

h

Response which is triggered if the threshold set in

C00572

for monitoring brake resistor utilisation is reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00576 | SC: Optimisation of field feedforward control

Data type: UNSIGNED_16

Index: 23999

d

= 5DBF

h

Point of action of the direct-axis current setpoint precontrol for an early reduction of the field current. In this way,

the acceleration behaviour can be improved in the field weakening range.

• The entry [%] refers to the slip of the asynchronous motor.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

600 200 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1