C00103

Parameter | Name:

C00103 | Add. decel. time x

Data type: UNSIGNED_32

Index: 24472

d

= 5F98

h

The

L_NSet_1

FB: Additional deceleration times for the main setpoint

• The additional deceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the

L_NSet_1

FB.

Setting range

(min. value | unit | max. value)

0.000

s

999.999

Subcodes

Lenze setting

Info

C00103/1

0.000 s

Add. decel. time 1 ... 15

C00103/...
C00103/15

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000