1 scaling of position value, 2 setting of a static position offset, Scaling of position value – Lenze 8400 TopLine User Manual

Page 351: Setting of a static position offset, 6encoder/feedback system

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

351

6

Encoder/feedback system

6.3

Multi-Encoder (X8)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.3.5.1

Scaling of position value

If you click the Scaling of position value... button in the parameterisation dialog for the

encoder/feedback system in the category "Multi-Encoder (X8), you get to the respective

parameterisation dialog:

Short overview of the relevant parameters:

6.3.5.2

Setting of a static position offset

If, for example, the encoder cannot be mounted mechanically in order that the supplied position

matches the mechanics or if for other reasons, a static position offset is required, this value can be

set in

C01112/1

.

Parameter

Info

Lenze setting

Value Unit

C01110

LS_MultiEncoder: Solid measure

• Setting of rotative or linear encoders.

Note: The selection "rotative" or "linear" only has an

impact if the encoder has not been detected

automatically or the encoder data definitely are to be

taken from the codes (bit 0 in

C00499/1

is set to "1").

The "unipolar" or "bipolar" selection definitely has an

impact.

0: rotatively unipolar

Settings for linear SinCos absolute value encoder with HIPERFACE® protocol

C01111/1

LS_MultiEncoder: Difference - traverse path

• Specification of the traverse path while passing

through the step number of the Hiperface track

given in

C01111/2

.

• Setting is relevant for parameter channel.

1 units

C01111/2

LS_MultiEncoder: Difference - encoder path

• Step number of the Hiperface track.

• Setting is relevant for parameter channel.

1 Steps

C01111/3

LS_MultiEncoder: Traverse path - encoder increment

• Specification of the traverse path while passing

through the number of increments of the SinCos

track given in

C00420/3

.

• Setting is relevant for process data channel

(incremental SinCos track).

1 units

Further settings

C01204

MCK: Feed constant

360.0000 units/rev.

Advertising