19 function library – Lenze 8400 TopLine User Manual

Page 1687

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1687

19

Function library

19.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01157/1...16

0.0000

units

214748.0000 Position switch point positions

• Lenze setting: 0.0000 units

dnSwitchPointx_p = position of the first switching point for position switch point x.

dn2ndPoint_Sizex_p = position of the second switching point or size of the

switching window for position switch point x, depending on the CenterMode set in

C01154/x

:

• When CenterMode = FALSE: Position of the second switching point

• dn2ndPoint_Sizex_p must be higher than dnSwitchPointx_p.

• When CenterMode = TRUE: Size of the switching window

• Due to the symmetrical arrangement of the window around the first switching

point, uneven values are rounded to even values.

• Only positive values are permissible.

C01158/1

Setting is bit coded:

Inversion of outputs

• Lenze setting: 0x0000

Bit 0 Inversion of output 1
Bit 1 Inversion of output 2
Bit 2 Inversion of output 3
Bit 3 Inversion of output 4
Bit 4 Inversion of output 5
Bit 5 Inversion of output 6
Bit 6 Inversion of output 7
Bit 7 Inversion of output 8
Bit 8 Reserved

...

Bit 15

For a detailed functional description see

L_SwitchPoint_1

.

Parameter

Possible settings

Info