17.2

Parameter list | C00148

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00148

Parameter | Name:

C00148 | LS_DriveInterface: Error message config.

Data type: UNSIGNED_16

Index: 24427

d

= 5F6B

h

Selection of the device statuses for which the bCollectedFail group error output of SB

LS_DriveInterface

is to be set

to TRUE.
Setting range

(min. hex value | max. hex value)

Lenze setting

0x0000

0xFFFF 0x0030 (decimal: 48)

Value is bit-coded: (= bit set)

Info

Bit 0  SafeTorqueOff
Bit 1  ReadyToSwitchOn
Bit 2  SwitchedOn
Bit 3  TroubleQSP
Bit 4  Trouble
Bit 5  Fault
Bit 6  Warning
Bit 7  ImpIsActive
Bit 8  CInhIsActive
Bit 9  Fail CAN_Management

Bit 10 

Reserved

Bit 11 

Reserved

Bit 12 

Reserved

Bit 13 

Reserved

Bit 14  Lock bFail at TroubleQSP

From version 02.00.00

1 ≡ The bFail output of the SB

LS_DriveInterface

is also

set in the "TroubleQSP" status.

• Advantage: Even in the "TroubleQSP" status, an error

occurred before can still be recognised.

Bit 15  Use 16BitFailNo.

1 ≡ The short 16-bit error number

wStateDetermFailNoShort is provided at the

wStateDetermFailNoLow output of the

SB

LS_DriveInterface

.

• In this case, the wStateDetermFailNoHigh output is

"0".

• Advantage: The bus transfer of the error numbers is

possible via a data word without changing the

interconnection of the technology application.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT