Os2: max. motor speed [xx.0123.00033, Id3: cinh identification [xx.0123.00058, Id4: resistor identification error [xx.0123.00059 – Lenze 8400 TopLine User Manual

Page 712: Os2: max. motor speed reached, Xx.0123.00057, Xx.0123.00056, Xx.0123.00058, Xx.0123.00059, Xx.0123.00033, 10 diagnostics & error management

Advertising
background image

10

Diagnostics & error management

10.9

Error messages of the operating system

712

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

oS2: Max. motor speed [xx.0123.00033]

Id2: Motor data identification error [xx.0123.00056]

Id1: Motor data identification error [xx.0123.00057]

Id3: CINH identification [xx.0123.00058]

Id4: Resistor identification error [xx.0123.00059]

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has recognised that the maximally

permissible motor speed has been reached.

• Limit setpoint selection to the maximally permissible

motor speed.

• If required, adapt set maximum motor speed

(

C00965

).

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

During the identification of the motor parameters, an

error has occurred that caused an abortion of the

identification process.

Possible causes:

• Interrupted motor cable.

• Switched-off power section during the identification.

• Implausible start parameter settings.

• Check the motor connections and the corresponding

plug connector on the device and, if necessary, the

motor terminal box.

• Correct start parameters for the motor parameter

identification (motor nameplate data).

• Stable power supply of the device.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

During the identification of motor parameters, an error

has occurred.

Possible causes:

• Interrupted motor cable.

• Switched-off power section during the identification.

• Implausible start parameter settings.

• Check the motor connections and the corresponding

plug connector on the device and, if necessary, the

motor terminal box.

• Correct start parameters for the motor parameter

identification (motor nameplate data).

• Stable power supply of the device.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has detected controller inhibit during the

motor data identification.

• This cancels the identification process. The Lenze

setting of the motor data is used.

• Do not set controller inhibit during the motor data

identification.

• Do not execute any device function which may

activate controller inhibit.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has recognised that an error has occurred in

the calculation of the motor cable resistance.

• The parameters for cable cross-section and cable

length are implausible.

Enter sensible values for cable cross-section and motor

cable length.

Advertising