C00121 | warning threshold motor temperature, C00122 | initial value motor overload (i·xt), C00123 | device utilisation threshold (ixt) – Lenze 8400 TopLine User Manual

Page 913: C00129 | brake resistance value, C00123, C00129, C00122, Ce parameterised in, Set in, C00121/1

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

913

17

Parameter reference

17.2

Parameter list | C00121

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00121

C00122

C00123

C00129

Parameter | Name:

C00121 | Warning threshold motor temperature

Data type: UNSIGNED_16

Index: 24454

d

= 5F86

h

Operating threshold for error message "Motor: Temperature at Res./Enc. > C121"

• The response for reaching the threshold can be selected in

C00583

.

• The current motor temperature is displayed in

C00063

.

Encoder/feedback system: Motor temperature monitoring (KTY)

Setting range

(min. value | unit | max. value)

0

°C

250

Subcodes

Lenze setting

Info

C00121/1

120 °C

Warning threshold motor temperature resolver

C00121/2

120 °C

Warning threshold motor temperature MultiEncoder

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00122 | Initial value motor overload (I²xt)

Data type: UNSIGNED_16

Index: 24453

d

= 5F85

h

From version 12.00.00

The thermal motor load displayed in

C00066

is pre-initialised with the value set here when the device is connected

to the mains.

• If "100.00 %" is set, the last value at switching off the device is used for the initialisation.

• Recommended setting for operation according to UL: 50.00 %

Motor overload monitoring (I2xt)

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C00122/1

0.00 %

Initial value motor overload (I²xt)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00123 | Device utilisation threshold (Ixt)

Data type: INTEGER_16

Index: 24452

d

= 5F84

h

Operating threshold for the "OC5: Device overload (Ixt)" error message

• The response for reaching the threshold can be selected in

C00604

.

• The current device utilisation is displayed in

C00064

.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

200.00 100.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00129 | Brake resistance value

Data type: UNSIGNED_16

Index: 24446

d

= 5F7E

h

Resistance value of the connected brake resistor

• The value to be entered can be obtained from the nameplate of the brake resistor.

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

Ohm

500.0 39.0 Ohm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10