C00828 | l_digitallogic_3: function, 17 parameter reference – Lenze 8400 TopLine User Manual

Page 1074

Advertising
background image

17

Parameter reference

17.2

Parameter list | C00828

1074

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00828

C00827/3

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 0 0 1 0

C00827/4

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 0 0 1 1

C00827/5

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 0 1 0 0

C00827/6

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 0 1 0 1

C00827/7

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 0 1 1 0

C00827/8

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 0 1 1 1

C00827/9

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 0 0 0

C00827/10

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 0 0 1

C00827/11

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 0 1 0

C00827/12

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 0 1 1

C00827/13

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 1 0 0

C00827/14

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 1 0 1

C00827/15

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 1 1 0

C00827/16

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=0 1 1 1 1

C00827/17

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 0 0 0

C00827/18

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 0 0 1

C00827/19

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 0 1 0

C00827/20

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 0 1 1

C00827/21

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 1 0 0

C00827/22

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 1 0 1

C00827/23

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 1 1 0

C00827/24

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 0 1 1 1

C00827/25

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 0 0 0

C00827/26

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 0 0 1

C00827/27

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 0 1 0

C00827/28

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 0 1 1

C00827/29

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 1 0 0

C00827/30

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 1 0 1

C00827/31

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 1 1 0

C00827/32

0: FALSE

L_DigitalLogic5_2

: bIn5...bIn1=1 1 1 1 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00827 | L_DigitalLogic5_2: Truth table

Data type: UNSIGNED_8

Index: 23748

d

= 5CC4

h

Parameter | Name:

C00828 | L_DigitalLogic_3: Function

Data type: UNSIGNED_8

Index: 23747

d

= 5CC3

h

From version 02.00.00

The

L_DigitalLogic_3

FB: Selection of the internal logic function

Selection list

(Lenze setting printed in bold)

Info

0 bOut = 0

Constant value "FALSE"

1 bOut = 1

Constant value "TRUE"

2 bOut = bIn1 AND bIn2 AND bIn3

AND operation

3 bOut = bIn1 OR bIn2 OR bIn3

OR operation

4 bOut = f (truth table)

The truth table parameterised in

C00829

is used.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1