C00052 | motor voltage, C00053 | dc-bus voltage, C00054 | motor current – Lenze 8400 TopLine User Manual

Page 897: C00055 | actual values, C00053, C00054, C00052, C00830/32, C00830/31, Apparen

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

897

17

Parameter reference

17.2

Parameter list | C00052

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00052

C00053

C00054

C00055

Parameter | Name:

C00052 | Motor voltage

Data type: UNSIGNED_16

Index: 24523

d

= 5FCB

h

Display of the current motor voltage/output voltage of the inverter
Display range

(min. value | unit | max. value)

0

V

1000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00053 | DC-bus voltage

Data type: UNSIGNED_16

Index: 24522

d

= 5FCA

h

Display of the current DC-bus voltage
Display range

(min. value | unit | max. value)

0

V

1000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00054 | Motor current

Data type: UNSIGNED_16

Index: 24521

d

= 5FC9

h

Display of the current motor current/output current of the inverter
Display range

(min. value | unit | max. value)

0.00

A

300.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00055 | Actual values

Data type: INTEGER_16

Index: 24520

d

= 5FC8

h

Actual value of the encoder/feedback system

Note:

When a single-track feedback has been selected for the HTL encoder (

C00115

= 1 or 3), the sign of the actual speed

value is created from the sign of the speed setpoint. In C00055/1 und C00055/2, a positive speed is always

displayed.

Encoder/feedback system

Display range

(min. value | unit | max. value)

-32767

rpm

32767

Subcodes

Info

C00055/1

Actual value - HTL encoder FreqIn12

C00055/2

Actual value - HTL encoder FreqIn67

C00055/3

Actual value - multi-encoder

C00055/4

Actual value - resolver

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1