C00370 | synctxrxtimes, C00371 | can errorcode, C00372 | can_tx_rx_error – Lenze 8400 TopLine User Manual

Page 964: C00381 | can heartbeat producer time, C00381, To 10, C00370/1, C00370/2, 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C00370

964

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00370

C00371

C00372

C00381

Parameter | Name:

C00370 | SyncTxRxTimes

Data type: INTEGER_16

Index: 24205

d

= 5E8D

h

System bus "CAN on board"

Display range

(min. value | unit | max. value)

-1310

μs

1310

Subcodes

Info

C00370/1

CAN Sync instant of transmission

C00370/2

Sync instant of reception

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00371 | CAN ErrorCode

Data type: UNSIGNED_16

Index: 24204

d

= 5E8C

h

From version 13.00.00

System bus "CAN on board"

Display range

(min. value | unit | max. value)

0

65535

Subcodes

Info

C00371/1

CAN ErrorCode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00372 | CAN_Tx_Rx_Error

Data type: UNSIGNED_8

Index: 24203

d

= 5E8B

h

"CAN on board" system bus

Display range

(min. value | unit | max. value)

0

255

Subcodes

Info

C00372/1

CAN Tx_Error

C00372/2

CAN Rx_Error

C00372/3

CAN Tx_Overflow

C00372/4

CAN Rx_Overflow

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00381 | CAN Heartbeat producer time

Data type: UNSIGNED_16

Index: 24194

d

= 5E82

h

Time interval for the transmission of the heartbeat telegram to the consumer(s).

• The heartbeat telegram is sent automatically as soon as a time > 0 ms is set.

• Mapping of the CANopen object

I-1017

(see DS301 V4.02).

Heartbeat protocol

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1