C01237 | mck: acceleration follower, C01238 | mck: s-ramp time follower, C01239 | setpoint holding – Lenze 8400 TopLine User Manual

Page 1188: C01239, Etting rule, C01237/1, C01237/2, C01238/1, 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01237

1188

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01237

C01238

C01239

Parameter | Name:

C01237 | MCK: Acceleration follower

Data type: INTEGER_32

Index: 23338

d

= 5B2A

h

Accelerations for position follower

Position follower

Setting range

(min. value | unit | max. value)

-214748.3647

units/s2

214748.3647

Subcodes

Lenze setting

Info

C01237/1

720.0000 units/s2

Pos follower: Sync. accel.

• Acceleration for ramp-up to synchronisation speed.

C01237/2

720.0000 units/s2

Pos follower: Sync. decel.

• Deceleration for synchronisation speed ramp-down

to standstill (to the setpoint position of the master).

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01238 | MCK: S-ramp time follower

Data type: UNSIGNED_16

Index: 23337

d

= 5B29

h

S-ramp times for position follower

• Setting "0 s" ≡ no rounding

Position follower

Setting range

(min. value | unit | max. value)

0.000

s

10.000

Subcodes

Lenze setting

Info

C01238/1

0.000 s

Pos follower: Sync. S-ramp time

• S-ramp time for the synchronisation speed ramps.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01239 | Setpoint holding

Data type: UNSIGNED_32

Index: 23336

d

= 5B28

h

From version 12.00.00

Setpoint holding for bus runtime compensation

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

32 0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising