14

Axis bus

14.2

Data transfer axis bus

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

[14-1] Transfer mechanisms

The axis bus data is transferred in 1-ms transmission cycle:

[14-2] Data transfer

The axis bus data transfer is connected to the master/slave application via the LS_AxisBus systems

blocks:

• For a data transfer from the master to all slaves (@all) and/or a cascaded data transfer (cas), the

systems blocks

LS_AxisBusIn

and

LS_AxisBusOut

are available in the FB Editor.

• For a data transfer from the master to a certain slave (@sel), the

LS_AxisBusAux

system block is

available.

0DVWHU



6ODYH



6ODYH



6ODYH



6ODYH



#DOO

7RS/LQH

7RS/LQH

7RS/LQH

7RS/LQH

7RS/LQH

FDV

#VHO

#DOO

FDV

#VHO

FDV

#DOO

FDV

#VHO

FDV

#DOO

FDV

#VHO

FDV

#DOO

FDV

#VHO

#VHO

#VHO

#VHO

#VHO

#VHO

:5,7(

5($'

F\FOH

F\FOH

F\FOH

Case 1:

Master sends setpoints

Slave works with new data

Case 2:

Master requests slave to send

Slave sends as requested

Data is processed by master

#DOO

FDV #VHO

#DOO

FDV #VHO





#DOO

FDV #VHO



#DOO

FDV #VHO



W>PV@