Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1285

17

Parameter reference

17.2

Parameter list | C02864

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Bit 6 Motor ident.: No calculation C577

C578 C2864

From version 15.00.00

: Following successful motor

parameter identification, the field weakening controller

parameters for ASM servo control are calculated as well.

If these parameters are not to be calculated, bit 6 must

be set to "1".

0 ≡ Calculate parameter

1 ≡ Do not calculate parameter

Automatic motor data identification

Bit 7 If C2879 Bit1=0: C087 is warm

From version 15.00.00

, the too high slip with the

activated option "Slip calculation from motor nameplate

data" can be corrected for the ASM servo control by

setting bit 7 to "1".

1 ≡ Rated motor speed (

C00087

) is assumed for a warm

machine.

Slip calculation for SC

Bit 8 Suppress V/f emergency operation

From version 15.00.00

, it is internally switched to the

encoderless V/f characteristic control in case of a motor

control type with feedback and an encoder open circuit

in order to avoid impermissible motor movements.

Exception: There will be no change-over in case of

servo control for synchronous motors (PSM).

• In order that this "V/f emergency operation" works

properly, the parameters relevant for the V/f

characteristic control (base frequency, Vmin boost,

slip compensation, etc.) have to be set correctly. As an

alternative, a motor parameter identification can be

executed as well.

• The change-over to "V/f emergency operation" is

reported via bit 4 in

C01000

and via the

bWirebreakUfLinearActive status signal at the

SB

LS_DeviceMonitor

.

• The setting in

C00006

is not affected by the change-

over.

The "V/f emergency operation" can be suppressed by

setting bit 8 to "1".

0 ≡ V/f emergency operation in case of encoder open

circuit

1 ≡ No V/f emergency operation in case of encoder open

circuit

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C02864/1

0x0000

MCTRL

: Optimisations

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02864 | MCTRL: Optimisiations

Data type: UNSIGNED_16

Index: 21711

d

= 54CF

h