10.9

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

FC01: Switching frequency reduction [xx.0123.00094]

FC02: Maximum speed for Fchop [xx.0123.00095]

oC14: Direct-axis current controller limitation [xx.0123.00096]

oC15: Cross current controller limitation [xx.0123.00097]

oC16: Torque controller limitation [xx.0123.00098]

Response (Lenze setting printed in bold)

Setting:

C00590

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Load-dependent switching frequency reduction

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Response (Lenze setting printed in bold)

Setting:

C00588

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Maximum speed for chopper frequency has been

reached.

• The maximum speed has been exceeded depending

on the switching frequency.

Select the correct maximum speed as a function of the

switching frequency.

Motor control: Determine speed limits

Response (Lenze setting printed in bold)

Setting:

C00570/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Direct-axis current controller limitation is active.

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Response (Lenze setting printed in bold)

Setting:

C00570/2

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Cross current controller limitation is active.

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

• Check parameter setting of the current controller

with regard to the motor controllers (e.g. reduce Vp).

Motor control

Response (Lenze setting printed in bold)

Setting:

C00570/3

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Actuator limitation according to speed controller.

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Advertising