Id6: resolver ident. error [xx.0123.00075, Id5: pole position identification error, Xx.0123.00074 – Lenze 8400 TopLine User Manual

Page 714: Xx.0123.00075, Xx.0123.00090, Xx.0123.00093, 10 diagnostics & error management

Advertising
background image

10

Diagnostics & error management

10.9

Error messages of the operating system

714

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Id5: Pole position identification error [xx.0123.00074]

Id6: Resolver ident. error [xx.0123.00075]

oC13: Maximum current for Fch exceeded [xx.0123.00090]

ot2: Speed controller output limited [xx.0123.00093]

Response (Lenze setting printed in bold)

Setting:

C00643/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

With 360° pole position identification:

• The rotor position detected via the encoder system

does not comply with the controlled output position

(plausibility check).

With pole position identification with minimum

movement:

• The encoder system has detected a movement that is

greater than the permitted movement set in

C00645/1

.

With 360° pole position identification:

• Check parameter setting of the pole position

identification.

• If required, adapt error tolerance for plausibility check

in

C00645/2

.

With pole position identification with minimum

movement:

• If required, adjust permitted movement in

C00645/1

.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

• A controller inhibit was set during resolver error

identification.

• A time-out occurred while the algorithm was being

processed. This error may occur if more than 60

seconds pass by between the setting of the "Resolver

error identification" device command and the enable

of the controller.

• The setpoint speed was too small (|nset| < 500 rpm).

• The setpoint speed was not traversed for at least 1

second.

• Reduce the gain of the speed controller.

• Check the shielding of the motor and encoder.

• Check encoder/encoder connection.

• Controller is enabled after the "Resolver error

identification" device command has been set.

• Ensure that the speed profile is traversed for at least 1

second at constant setpoint speed (|nset| > 500 rpm).

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has detected a motor current which exceeds

the maximum current limit at permanent switching

frequency of the inverter.

• If a permanent switching frequency inverter is set, a

certain limit arises for the maximum current,

depending on the setting. If this current limit is

exceeded due to a load impulse or overload, an error

message is displayed.

• Observe the maximum current setting depending on

the set switching frequency of the inverter.

• Reduce the required load or setting of the dynamic

switching frequency if necessary.

Response (Lenze setting printed in bold)

Setting:

C00567

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The output of the speed controller has reached the

internal limit value. In this status, the speed controller is

not able anymore to correct the system deviation.

• Only during "Closed loop" operation or with vector

control (SLVC).

• Observe load requirements.

• Correct dimensioning or reduce setpoint generation

dynamics if necessary.

Motor control

Advertising