16 parameter change-over – Lenze 8400 TopLine User Manual
Page 871
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
871
16
Parameter change-over
16.4
Internal interfaces | System block "LS_WriteParamList"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
Identifier
Data type
Value/meaning
bDone
BOOL
"Writing of the parameter list completed" status signal
• The output is automatically reset to FALSE if writing via bExecute is activated
again.
TRUE Writing of the parameter list successfully completed.
FALSE The FALSE status can have the following meanings:
1.There is no active writing of the parameter list.
2.Writing of the parameter list has not been completed yet.
3.An error has occurred (if bFail = TRUE).
bFail
BOOL
"Error" status
TRUE An error has occurred (group signal).
• See display parameter
) for details.