Oc5: ixt overload [xx.0119.00050, Ot1: maximum torque reached [xx.0123.00001, Oc7: motor overcurrent [xx.0123.00007 – Lenze 8400 TopLine User Manual

Page 708: Oc5: ixt overload, Oc7: motor overcurrent, Ot1: maximum torque reached, Sd12: thermal detector error - multiencoder, Xx.0119.00050, Xx.0123.00007, Xx.0123.00001

Advertising
background image

10

Diagnostics & error management

10.9

Error messages of the operating system

708

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Sd12: Error thermal detector MultiEncoder [xx.0119.00022]

oC5: Ixt overload [xx.0119.00050]

ot1: Maximum torque reached [xx.0123.00001]

oC7: Motor overcurrent [xx.0123.00007]

Response (Lenze setting printed in bold)

Setting:

C00583/6

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The signals of the encoder connected to the encoder

interface are outside the defined operating range of the

motor temperature detection.

• Check contacts of the encoder cable at the motor and

controller.

• Check the selected motor temperature sensor in

C01190/2

as to whether it complies with the

assembly in the motor.

• If required, switch off thermal sensor monitoring

(

C00583/6

="0").

Response (Lenze setting printed in bold)

Setting:

C00604

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The Ixt overload check has tripped.

• Operating threshold = 100 % Ixt (adjustable in

C00123

)

Possible causes:

• Wrong dimensioning of the device with regard to its

motor load.

• Load cycles are not complied with.

• Check and, if required, correct dimensioning of the

device and the motor load with regard to technical

data.

• Reduce motor load cycles (observe load cycles

according to documentation).

Response (Lenze setting printed in bold)

Setting:

C00608

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device indicates that the maximally possible torque

at the motor shaft has been reached.

C00057

displays the current torque.

Reduce motor load.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Maximum current monitoring has tripped.

• The instantaneous value of the motor current has

exceeded the limit value set in

C00939

.

Check and, if required, correct dimensioning of the load

with regard to the installed device power.

Advertising