C01150 | l_phaseintk: function, C01151 | l_phaseintk: compare, C01152 | l_switchpointpar_1: dead time – Lenze 8400 TopLine User Manual

Page 1170: 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01150

1170

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01150

C01151

C01152

Parameter | Name:

C01150 | L_PhaseIntK: Function

Data type: UNSIGNED_8

Index: 23425

d

= 5B81

h

Loading behaviour of the integrator
Selection list

Info

0 Loading with level

Load integrator with TRUE level at the input bLoad

1 Loading with edge

Load integrator with FALSE/TRUE edge at the input

bLoad

2 Loading with level + reset

Load integrator when the comparison value (

C01151

) is

reached or with TRUE level at the bLoad input

Subcodes

Lenze setting

Info

C01150/1

0: Loading with level

L_PhaseIntK_1

: Function

C01150/2

0: Loading with level

L_PhaseIntK_2

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01151 | L_PhaseIntK: Compare

Data type: INTEGER_32

Index: 23424

d

= 5B80

h

Comparison value
Setting range

(min. value | unit | max. value)

0

2147418112

Subcodes

Lenze setting

Info

C01151/1

0

L_PhaseIntK_1

: Comparison value

C01151/2

0

L_PhaseIntK_2

: Comparison value

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01152 | L_SwitchPointPar_1: Dead time

Data type: UNSIGNED_16

Index: 23423

d

= 5B7F

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0

65535

Subcodes

Lenze setting

Info

C01152/1

0

L_SwitchPointPar_1

: Dead time 1

C01152/2

0

L_SwitchPointPar_1

: Dead time 2

C01152/3

0

L_SwitchPointPar_1

: Dead time 3

C01152/4

0

L_SwitchPointPar_1

: Dead time 4

C01152/5

0

L_SwitchPointPar_1

: Dead time 5

C01152/6

0

L_SwitchPointPar_1

: Dead time 6

C01152/7

0

L_SwitchPointPar_1

: Dead time 7

C01152/8

0

L_SwitchPointPar_1

: Dead time 8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1