17

Parameter reference

17.2

Parameter list | C00761

1064

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00761

C00760/22

0: Not connected

LA_SwitchPos

: wFreeIn1

Input for user signal 1

C00760/23

0: Not connected

LA_SwitchPos

: wFreeIn2

Input for user signal 2

C00760/24

0: Not connected

LA_SwitchPos

: wFreeIn3

Input for user signal 3

C00760/25

0: Not connected

LA_SwitchPos

: wFreeIn4

Input for user signal 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00760 | LA_SwitchPos: Analog connection list

Data type: UNSIGNED_16

Index: 23815

d

= 5D07

h

Parameter | Name:

C00761 | LA_SwitchPos: Digital connection list

Data type: UNSIGNED_16

Index: 23814

d

= 5D06

h

Connection parameters for "Switch-off positioning" application: Binary inputs

• Selection of the binary output signals to be connected to the binary input signals

• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the

subcodes.

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00761/1

0: Not connected

LA_SwitchPos

: bCInh

Control input for setting controller inhibit

C00761/2

0: Not connected

LA_SwitchPos

: bFailReset

Control input for error acknowledgement

C00761/3

0: Not connected

LA_SwitchPos

: bSetQuickstop

Control input for quick stop request

C00761/4

0: Not connected

LA_SwitchPos

: bSetDCBrake

Control input for DC-injection braking request

C00761/5

0: Not connected

LA_SwitchPos

: bRFG_Stop

Control input for stopping the speed ramp function

generator

C00761/6

0: Not connected

LA_SwitchPos

: bSetSpeedCcw

Control input for change of direction of rotation

C00761/7

0: Not connected

LA_SwitchPos

: bRLQCw

Control input for activation of CW rotation (fail-safe)

C00761/8

0: Not connected

LA_SwitchPos

: bRLQCcw

Control input for activation of CCW rotation (fail-safe)

C00761/9

0: Not connected

LA_SwitchPos

: bJogCtrlInputSel1

Selection input 1 for binary coded selection of the

switch-off position 1 ... 3

C00761/10

0: Not connected

LA_SwitchPos

: bJogCtrlInputSel2

Selection input 2 for binary coded selection of the

switch-off position 1 ... 3

C00761/11

0: Not connected

LA_SwitchPos

: bJogCtrlRfgIn

Control input for setpoint generator ramp-down

C00761/12

0: Not connected

LA_SwitchPos

: bJogCtrlJog1

Selection input 1 for overriding fixed setpoints (JOG

setpoints) for the main setpoint

C00761/13

0: Not connected

LA_SwitchPos

: bJogCtrlJog2

Selection input 2 for overriding fixed setpoints (JOG

setpoints) for the main setpoint