C00451 | ls_multiencoder: bfail information, C00451/1, 17 parameter reference – Lenze 8400 TopLine User Manual

Page 984

Advertising
background image

17

Parameter reference

17.2

Parameter list | C00451

984

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00451

Parameter | Name:

C00451 | LS_MultiEncoder: bFail information

Data type: UNSIGNED_16

Index: 24124

d

= 5E3C

h

From version 14.00.00

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Encoder open circuit
Bit 1 KTY open circuit
Bit 2 Position beyond C1112/2..3
Bit 3 Angular drift error
Bit 4 Communication error
Bit 5 Hiperface position invalid
Bit 6 Linear data overflow SSI
Bit 7 Max. encoder speed
Bit 8 Hiperface init active
Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Info

C00451/1

LS_MultiEncoder

: bFail information

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising