C00451 | ls_multiencoder: bfail information, C00451/1, 17 parameter reference – Lenze 8400 TopLine User Manual
Page 984
17
Parameter reference
17.2
Parameter list | C00451
984
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00451
Parameter | Name:
C00451 | LS_MultiEncoder: bFail information
Data type: UNSIGNED_16
Index: 24124
d
= 5E3C
h
From version 14.00.00
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Encoder open circuit
Bit 1 KTY open circuit
Bit 2 Position beyond C1112/2..3
Bit 3 Angular drift error
Bit 4 Communication error
Bit 5 Hiperface position invalid
Bit 6 Linear data overflow SSI
Bit 7 Max. encoder speed
Bit 8 Hiperface init active
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Info
C00451/1
: bFail information
Read access Write access CINH PLC STOP No transfer COM MOT