3 internal interfaces | system block "ls_axisbusio, Internal interfaces | system block "ls_axisbusio, Ls_axisbusio – Lenze 8400 TopLine User Manual

Page 856: 14 axis bus

Advertising
background image

14

Axis bus

14.3

IO axis bus

856

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.3.3

Internal interfaces | System block "LS_AxisBusIO"

The LS_AxisBusIO system block maps the IO axis bus in the FB Editor:

Inputs

Outputs

Identifier

Data type

Information/possible settings

bSetFail_DigOut

BOOL

Set IO axis bus into the "error" status / IO data exchange

TRUE

or

FALSETRUE

For all IO axis bus nodes, the bFail_DigIn output is set to TRUE.

From version 12.00.00 onwards

, bit 0 in

C02444/1

can be used to

reconfigure the bSetFail_DigOut input from level-sensitive to

edge-sensitive.

bResetFail

BOOL

Reset "error" status

• Only possible with "Master/slave" function via the IO axis bus master.

FALSETRUE For all IO axis bus nodes, the bFail_DigIn output is reset to FALSE.

After a delay time of 2 ms, the bResetFail_In output is set to TRUE for

3 ms for error reset.

Identifier

Data type

Value/meaning

bFail_DigIn

BOOL

With "master/slave" function: "Error" status

With "IO" function: Data exchange

TRUE An IO axis bus nodes has set the bSetFail_Digout input to TRUE.

bResetFail_In

BOOL

"Error" status has been reset

• With "IO" function, this output is always FALSE.

TRUE The IO axis bus master has reset the error message.

This status is only pending for 3 ms.

/6B$[LV%XV,2

E6HW)DLOB'LJ2XW

E5HVHW)DLO

E)DLOB'LJ,Q

E5HVHW)DLOB,Q