17

Parameter reference

17.2

Parameter list | C00701

1050

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00701

C00700/15

0: Not connected

LA_NCtrl

: nGPCompareIn2_a

Input for comparison operation - analog signal 2

C00700/16

0: Not connected

LA_NCtrl

: nVoltageAdd_a

Input for additive voltage boost

C00700/17

0: Not connected

LA_NCtrl

: nPIDInfluence_a

Input for influence signal of PID controller correcting

variable

C00700/18

0: Not connected

LA_NCtrl

: nPIDSetValue_a

Input for PID controller setpoint

C00700/19

0: Not connected

LA_NCtrl

: nPWMAngleOffset

Input for pulse width modulation phase offset

C00700/20

0: Not connected

LA_NCtrl

: nBoost_a

Input for additional setpoint for motor voltage at speed

= 0

C00700/21

0: Not connected

LA_NCtrl

: wSMCtrl

Interface to the optional safety system

C00700/22

0: Not connected

Reserved

C00700/23

0: Not connected

Reserved

C00700/24

0: Not connected

Reserved

C00700/25

0: Not connected

Reserved

C00700/26

0: Not connected

LA_NCtrl

: wFreeIn1

Input for user signal 1

C00700/27

0: Not connected

LA_NCtrl

: wFreeIn2

Input for user signal 2

C00700/28

0: Not connected

LA_NCtrl

: wFreeIn3

Input for user signal 3

C00700/29

0: Not connected

LA_NCtrl

: wFreeIn4

Input for user signal 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00700 | LA_NCtrl: Analog connection list

Data type: UNSIGNED_16

Index: 23875

d

= 5D43

h

Parameter | Name:

C00701 | LA_NCtrl: Digital connection list

Data type: UNSIGNED_16

Index: 23874

d

= 5D42

h

Connection parameters for "Actuating drive speed" application: Binary inputs

• Selection of the binary output signals to be connected to the binary input signals

• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the

subcodes.

Selection list
See

selection list - digital signals

Subcodes

Lenze setting

Info

C00701/1

0: Not connected

LA_NCtrl

: bCInh

Control input for setting controller inhibit

C00701/2

16008: LS_DigitalInput: bCInh

LA_NCtrl

: bFailReset

Control input for error acknowledgement

C00701/3

0: Not connected

LA_NCtrl

: bSetQuickstop

Control input for quick stop request

C00701/4

16002: LS_DigitalInput: bIn3

LA_NCtrl

: bSetDCBrake

Control input for DC-injection braking request

Advertising