C01902 | diagnostics x6: max. baud rate, C01903 | diagnostics x6: change baud rate, C01905 | diagnostics x6: current baud rate – Lenze 8400 TopLine User Manual

Page 1232: C02200 | ls_writeparamlist: function, C02200/1, C02200/2, 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01902

1232

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01902

C01903

C01905

C02200

Parameter | Name:

C01902 | Diagnostics X6: Max. baud rate

Data type: UNSIGNED_16

Index: 22673

d

= 5891

h

Maximally permissible baud rate in the standard device after determination of the baud rate at the diagnostic

interface X6
Selection list

(Lenze setting printed in bold)

192 19.200 Bd
384 38.400 Bd
576 57.600 Bd
750 75.000 Bd

1152 115.200 Bd
1500 150.000 Bd
2500 250.000 Bd
3750 375.000 Bd
7500 750.000 Bd

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01903 | Diagnostics X6: Change baud rate

Data type: UNSIGNED_8

Index: 22672

d

= 5890

h

New baud rate determination at the diagnostic interface X6
Selection list

(Lenze setting printed in bold)

0 Ignore changes
1 Negotiate baud rate

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01905 | Diagnostics X6: Current baud rate

Data type: UNSIGNED_32

Index: 22670

d

= 588E

h

Current baud rate at the diagnostic interface X6
Display range

(min. value | unit | max. value)

0

Bd

3000000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02200 | LS_WriteParamList: Function

Data type: UNSIGNED_8

Index: 22375

d

= 5767

h

From version 12.00.00

Configuration of which parameter lists are to be subject to the "

Parameter change-over

" function.

Selection list

0 Off
1 On

Subcodes

Lenze setting

Info

C02200/1

1: On

Definable parameter list

C02200/2

0: Off

Motor data parameter list

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1