173 l_transient_1, 173 l_transient_1 8, L_transient_1 – Lenze 8400 TopLine User Manual

Page 1688: 19 function library

Advertising
background image

19

Function library

19.1

Function blocks

1688

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.173

L_Transient_1

This FB serves to evaluate digital signal edges and convert them into timed, retriggerable pulses.

Rising signal edges, falling signal edges or both signal edges can be evaluated.

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

bIn

BOOL

Input for edge evaluation

• The function depends on the selection of edge evaluation in

C01138/1

.

Identifier

Data type

Value/meaning

bOut

BOOL

Output (retriggerable)

Parameter

Possible settings

Info

C01138/1

Function

• Selection of edge evaluation

0 High edge

Lenze setting

1 Low edge
2 High and low edge

C01139/1

0.001

s

60.000 Pulse duration