C00452 | ls_resolver: bfail information, C00453 | keypad: default manual jog, C00452/1 – Lenze 8400 TopLine User Manual
Page 985: 17 parameter reference
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
985
17
Parameter reference
17.2
Parameter list | C00452
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00452
C00453
C00455
Parameter | Name:
C00452 | LS_Resolver: bFail information
Data type: UNSIGNED_16
Index: 24123
d
= 5E3B
h
From version 14.00.00
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Resolver wire breakage
Bit 1 KTY open circuit
Bit 2
Reserved
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Info
C00452/1
: bFail information
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00453 | Keypad: Default manual jog
Data type: UNSIGNED_32
Index: 24122
d
= 5E3A
h
From version 14.00.00
Setting range
(min. value | unit | max. value)
0.000
16000.000
Subcodes
Lenze setting
Info
C00453/1
729.001
Keypad: Speed setpoint
C00453/2
56.002
Keypad: Display bar
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00455 | FB_call table
Data type: UNSIGNED_16
Index: 24120
d
= 5E38
h
This code is for device-internal use only and must not be written to by the user!