Parameterisation dialog (cutout)

Parameter

Info

Lenze setting

Value Unit

Settings for HTL encoder at DI1/DI2

C00115/1

Fct. DI 1/2 200kHz

• Function of the digital inputs DI1 and DI2

0: DI1(6)=In / DI2(7)=In

C00420/1

FreqIn12: Encoder increment

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

128 Incr./rev.

C00497/1

FreqIn12: Encoder filter time

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

1.0 ms

C00425/1

FreqIn12: Encoder scanning time

• If the digital inputs DI1 and DI2 are used as

encoder inputs.

10 ms

C00496

Encoder evaluation method DigIn12 ( 355)

2: Comb. encoder method

Settings for HTL encoder at DI6/DI7

C00115/2

Fct. DI 6/7 10kHz

• Function of the digital inputs DI6 and DI7

0: DI1(6)=In / DI2(7)=In

C00420/2

FreqIn67: Encoder increment

• If the digital inputs DI6 and DI7 are used as

encoder inputs.

128 Incr./rev.

C00497/2

FreqIn67: Encoder filter time

• If the digital inputs DI6 and DI7 are used as

encoder inputs.

1.0 ms

C00425/2

FreqIn67: Encoder scanning time

• If the digital inputs DI6 and DI7 are used as

encoder inputs.

10 ms