7 monitoring, Monitoring, 6encoder/feedback system – Lenze 8400 TopLine User Manual

Page 368

Advertising
background image

6

Encoder/feedback system

6.7

Monitoring

368

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.7

Monitoring

Parameterisation dialog (cutout)

Parameter

Info

Lenze setting

Value Unit

C00498

Open-circuit monitoring

0: Speed encoder and position

encoder

C00586

Resp. open circuit HTL encoder

1: Fault

C00603/1

Resp. to MultiEncoder open circuit

1: Fault

C00603/2

Resp. to resolver open circuit

1: Fault

C00603/3

Up to and including version 02.xx.xx:

Resp. to encoder comm. error

1: Fault

From version 12.00.00:

Resp. to encoder pulse deviation

0: No Reaction

C00603/4

Up to and including version 02.xx.xx:

Resp. to encoder pulse deviation

1: Fault

From version 12.00.00:

Resp. to encoder comm. error

1: Fault

C00603/5

Resp. to Hiperface status

6: Information

C00603/6

Resp. to invalid Hiperface position

6: Information

C00603/7

Resp. to SinCos inaccuracy

6: Information

C00607

Resp. to max. freq. feedb. DIG12/67

1: Fault

Monitoring of encoder value (LS_MultiEncoder: bFail)

C01112/2

LS_MultiEncoder: Data area min

-214748.3647 units

C01112/3

LS_MultiEncoder: Data area max

214748.3647 units

C01112/4

LS_MultiEncoder: Max. position jump

0.0000 units

C00451/1

LS_MultiEncoder: Information bFail

-

Monitoring of encoder value (LS_Resolver: bFail)

C00452/1

LS_Resolver: Information bFail

-

Highlighted in grey = display parameter