19.1.158.6 Action type "positioning"

For starting a positioning, 50 actions of "positioning" type are available. The

Profile entry

is made via

the parameters of the basic function "

Positioning

".

Action call (entry in the sequence table)

with action number xxx = 001 ... 050

Parameter
The available actions 1 ... 50 are represented via the subcodes 1 ... 50.

Parameter

Possible settings

Info

C01405/1...50

Pos. action n: Starting with

0 Waiting function deactivated

In the default setting, the execution

of the profile is started immediately.

1 Sequencer input 1

(Bit 0 of wDigitalInputs)

"Wait for level": The execution of the

profile is only started when the

selected sequencer input has the

polarity set in

C01406/x

.

2 Sequencer input 2

(Bit 1 of wDigitalInputs)

... ...

16 Sequencer input 16

(Bit 15 of wDigitalInputs)

C01406/1...50

Pos. action n: Polarity input

• State of the sequencer input

required for starting the profile.

0 Condition is bit state "0"
1 Condition is bit state "1"

C01407/1...50

Pos. action n: Profile number

• A sequence profile can be set in

the corresponding profile

parameter.

0 No profile executed

1...15 Execute profile no. 1 ... 15

C01408/1...50

Pos. action n: Jump destination

• Step within the sequence table

which is processed after the

profile has been executed.

0 Sequence step

1...100 Step 1 ... 100

C01409/1...50

0.000

s

2147480.000 Pos. action n: Monitoring time

• If the positioning process lasts

longer than the monitoring time

set here, it is branched to the

jump destination set in

C01410/x

.

When "0.000 s" is set (Lenze setting), time

monitoring is deactivated.

C01410/1...50

Pos. action n: Jump destination

monitoring

• Step that is executed after the

monitoring time has been

exceeded.

0 Sequence step

1...100 Step 1 ... 100