C00425 | encoder scanning time, C00425/1, C00425/2 – Lenze 8400 TopLine User Manual
Page 972: C00425, 17 parameter reference
17
Parameter reference
17.2
Parameter list | C00425
972
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00425
Parameter | Name:
C00425 | Encoder scanning time
Data type: UNSIGNED_8
Index: 24150
d
= 5E56
h
Encoder sample time for the digital input terminals when configured as frequency inputs
Using DI1(6) and DI2(7) as frequency inputs
Selection list
0 1 ms
1 2 ms
2 5 ms
3 10 ms
4 20 ms
5 50 ms
6 100 ms
7 200 ms
8 500 ms
9 1000 ms
Subcodes
Lenze setting
Info
C00425/1
3: 10 ms
FreqIn12: Encoder scanning time
• Only active with edge-counting procedure
(
= 3).
C00425/2
3: 10 ms
FreqIn67: Encoder scanning time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1