Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

753

12

System bus "CAN on board"

12.2

Possible settings via DIP switch

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.2

Possible settings via DIP switch

The following settings for the "CAN on board" system bus can be made via the front panel DIP

switches:

Lenze setting: All DIP switches are in the "OFF" position

Tip!
The current DIP switch settings are displayed in code

C00349

.

Bit 15 indicates that the setting of the DIP switches has been accepted when the device or

the 24V supply has been switched on.

12.2.1

Activating the bus terminating resistor

The system bus must be terminated between CAN low and CAN high at the first and last physical

node each by a resistor (120 Ω).
The 8400 controller is provided with an integrated bus terminating resistor, which can be activated

via the DIP switch labelled with "CA":

[12-1] Activation of the integrated bus terminating resistor

DIP switch

Possible settings/detailed information

a ... c

Setting the baud rate

1 ... 64

Setting the node address

CA

Activating the bus terminating resistor

Note!

• The DIP switch settings are accepted if a node address is unequal zero when the device

or the 24-V supply is switched on by the DIP address.

• If all DIP switches are OFF when the device or the 24 V supply is switched on, the

setting of the baud rate and node address are read out of the parameter

set/parameter.

R

R

CA

AB

c b a 64 32 16 8 4 2 1

Baud

CAN Address

OFF

ON

• OFF = bus terminating resistor is inactive
• ON = bus terminating resistor is active

R

R

CA

AB

OFF

ON

120

Ù

CG

CL

CH

X1