6.7.4

Encoder value monitoring

For detecting invalid encoder values, a value range can be defined via the parameter

C01112/2

and

C01112/3

. When the encoder signal leaves the set value range, the bFail status signal of the

SB

LS_MultiEncoder

is set to TRUE and the corresponding information is displayed bit-coded in

C00451/1

.

Example 1: SSI laser distance meter

The bFail status signal can be used to detect an interruption of the laser beam or a dirty mirror.

Example 2: SSI bar code scanner

In an application, an SSI bar code scanner is used to detect the workpiece ID and the workpiece

position. A setting of sensible limit values serves to use the bFail status signal to determine

whether the ID or the position of the SSI bar code scanner has been detected.