Bit 17 PosFinishTarget

Control bit for completing processing of an interrupted

positioning profile

• 0->1 ≡ processing of a positioning profile which has

already been started and has been interrupted

because of a cancellation condition or a change of the

operating mode is completed in the "Positioning"

mode when the home position is known.

Note:

Completion of profile processing through this control is

based on the target position detected at the profile start!

Bit 18 PosDisableFollowProfile

Control bit for suppression of the sequence profile

• 1 ≡ positioning profiles whose profile numbers are

entered in profile data sets for sequence profiles are

not started after completion of the corresponding

profile.

Bit 19 PosStop

Control bit for stopping the positioning profile

• 0->1 ≡ ("Positioning" mode): Interrupts a running

profile through deceleration along the set

deceleration ramp to standstill.

• 0->1 ≡ ("Stop" mode): Starts a new deceleration to

standstill with the parameterised stop ramp.

Bit 20 PosModeBit0

Active positioning mode - control bit 0

Bit 21 PosModeBit1

Active positioning mode - control bit 1

Bit 22 PosModeBit2

Active positioning mode - control bit 2

Bit 23 PosModeBit3

Active positioning mode - control bit 3

Bit 24 ProfileNo_Bit0

Active positioning profile number - control bit 0

Bit 25 ProfileNo_Bit1

Active positioning profile number - control bit 1

Bit 26 ProfileNo_Bit2

Active positioning profile number - control bit 2

Bit 27 ProfileNo_Bit3

Active positioning profile number - control bit 3

Bit 28 ProfileNo_Bit4

Active positioning profile number - control bit 4

Bit 29 ProfileNo_Bit5

Active positioning profile number - control bit 5

Bit 30 ProfileNo_Bit6

Active positioning profile number - control bit 6

Bit 31 ProfileNo_Bit7

Active positioning profile number - control bit 7

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01240 | MCK: Control word

Data type: UNSIGNED_32

Index: 23335