9.8.4.3

Override of the parameterised positioning mode

The setting of the positioning mode in

MCK control word

superimposes the mode selection via the

"Mode" profile parameter (

C1300/1...15

). This means that for selected profiles the mode selection

and the request of a touch probe positioning via process data are possible. The value set in

C01300/1...15

is not overwritten. The following applies to the override:

A. Valid positioning mode in the MCK control word:

The positioning mode set in the MCK control word is used.

B. Positioning mode in the MCK control word = 0:

The positioning mode set in "mode" profile parameter (

C1300/1...15

) is used.

C. Invalid positioning mode in the MCK control word:

Ck09Error message "Ck09: Invalid positioning mode". The response set in

C00595/9

occurs

(Lenze setting: "WarningLocked").

Bit

Designation

Description

20

...

23

PosModeBit0

...

PosModeBit3

Positioning mode

Bit 3

Bit 2

Bit 1

Bit 0

Positioning mode = setting in

C01300/1...15

0

0

0

0

Absolute (shortest path)

0

0

0

1

Continuous

0

0

1

0

Relative

0

0

1

1

absolute (Cw)

0

1

0

0

absolute (Ccw)

0

1

0

1

Absolute (shortest path) to TP

1

0

0

0

Continuous to TP

1

0

0

1

Relative to TP

1

0

1

0

Absolute (Cw) on TP

1

0

1

1

Absolute (Ccw) on TP

1

1

0

0

All other possible settings are reserved for future extensions!