8 mci, 8technology applications – Lenze 8400 TopLine User Manual

Page 538

Advertising
background image

8

Technology applications

8.5

TA "Switch-off positioning"

538

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.5.3.8

MCI

Process data assignment for fieldbus communication

( 539)

Connection

Assignment

Connection

Assignment

X101/NC-NO

-

X5/RFR

LA_SwitchPos: bFailReset

X3/A1U

LA_SwitchPos.nAuxSetValue_a

10 V ≡ 100 % reference speed (

C00011

)

X5/DI1

LA_SwitchPos: bJogCtrlStop1

X3/A1I

X5/DI2

LA_SwitchPos: bJogCtrlSlowDown1

X3/A2U

-

X5/DI3

LA_SwitchPos: bJogCtrlStop2

X3/A2I

-

X5/DI4

LA_SwitchPos: bJogCtrlSlowDown2

X3/O1U

-

X5/DI5

LA_SwitchPos: bJogCtrlStop3

X3/O1I

-

X5/DI6

LA_SwitchPos: bJogCtrlSlowDown3

X3/O2U

-

X5/DI7

-

X3/O2I

-

X107/BD1

LA_SwitchPos.bMBrakeReleaseOut

X4/DO1

-

X107/BD2

-

X4/DO2

-

X4/DO3

-

Note!

You must set the setpoint arithmetic in

C00190

to "1: NOut = NSet + NAdd" so that the

additional speed setpoint selected via the analog input A1U has an additive effect.

X4

24B

24O

GB

DO1

BD2

DO3

GO

BD1

DO2

+

M

A2I

AR

COM

A1U

NC

A2U

A1I

NO

X3

DI3

DI2

DI4
DI5
DI6
DI7
GI

24I

DI1

RFR

GA

O1U

O1I

O2U

O2I

X101

24E

+

=

=

CG

CL

CH

X1

+

=

LP_MciIn

LP_MciOut

wCtrl

wIn2

wIn3...16

DriveControl

MainSetValue

-

wState

wOut2

wOut3

DriveControlStatus

MotorSpeedAct

GPSignalOut1

wOut4...16 -

X5

X107

Additional
speed setpoint

Controller enable / reset error

Stop function 1

Selection: Pre-switch off 1

Stop function 2

Selection: Pre-switch off 2

Stop function 3

Selection: Pre-switch off 3

External 24 V DC

supply

Brake released

Advertising