8 action type "branching, 8 action type "branching" 8, L_sequencer_1: "branch" action – Lenze 8400 TopLine User Manual

Page 1658: Branching, 19 function library, 3 x x x

Advertising
background image

19

Function library

19.1

Function blocks

1658

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.158.8 Action type "Branching"

For conditional and unconditional branching (jumps), 16 actions of "Branching" Type are available.

Action call (entry in the sequence table)

with action number xxx = 001 ... 016

Parameter
The available actions 1 ... 16 are represented via the subcodes 1 ... 16.

Parameter

Possible settings

Info

C01415/1...16

Branching action n: Input for jump

0 Unconditional branch

"Unconditional branch": It is always

branched to the jump destination set

in

C01417/x

.

1 Sequencer input 1

(Bit 0 of wDigitalInputs)

"Conditional branch": It is only

branched to the jump destination set

in

C01417/x

if the selected

sequencer input has the polarity set

in

C01416/x

.

• Otherwise, the following step in

the sequence table will be

processed.

2 Sequencer input 2

(Bit 1 of wDigitalInputs)

... ...

16 Sequencer input 16

(Bit 15 of wDigitalInputs)

C01416/1...16

Branching action n: Polarity input

• State of the selected sequencer

input required for a conditional

branch to the jump destination.

0 Condition is bit state "0"
1 Condition is bit state "1"

C01417/1...16

Branching act. n: Jump destination

• In case of unconditional branch, it

is always branched to the jump

destination set here.

• In case of conditional branch, it is

only branched to the jump

destination set here if the

sequencer input selected in

C01415/x

has the polarity set in

C01416/x

. Otherwise, the

following step in the sequence

table will be processed.

0 Sequence step

1...100 Step 1 ... 100

0

1

3 x x x